In many locations from chemistry laboratories to industrial facilities, in order to guarantee the protection of life and property in opposition to a attainable fire hazard, extinguishing systems are used along with detection and alarm techniques. It can also be extremely important that the extinguishing systems installed can be triggered by the fireplace extinguishing management panel, so as to remove a possible fire with early intervention.
In order to fulfill these needs, and with 35 years of sectoral information and expertise, Mavili Elektronik offers:
Maxlogic Conventional Fire Extinguishing Control Panel operating in accordance with the cross-zone detection principle;
Maxlogic Extinguishing Status Indicator Unit, which allows the remote efficiency of the indications and controls on the Control Panel;
Maxlogic Extinguishing Output Expansion Panel;
Maxlogic Extinguishant Manual Release Button, which allows the extinguishing course of to be started manually and remotely; and

to ensure that the extinguishing process could be paused, Maxlogic has produced the Extinguishant Emergency Stop Button.
All these gadgets are produced utilizing surface-mount expertise and are aimed toward making the automation of the extinguishing system and fireplace and gasoline detection system excellent.
Image copyright: Mavili

Mavili Elektronik develops its merchandise by at all times contemplating the needs of the installation. In circumstances that require the combination of the extinguishing system with the intelligent addressable fireplace detection system, it provides solutions by way of the monitoring modules that even have a ‘supervised’ option.
Supervised monitoring pressure gauge octa play an important function in controlling the continuity of the cable connection between the loop and the extinguishing system. Failure to detect a attainable open or short circuit within the wiring between the contact monitoring modules and the peripheral methods could cause disruption of the triggering, with doubtlessly crucial penalties. For this cause, when choosing monitoring modules, it ought to be taken into consideration that they’ve supervised options.
Image copyright: Mavili

Since Maxlogic clever addressable fire detection and alarm management panels are continually speaking with ‘supervise’ contact monitoring modules related to cable loops and compliant with EN 54-17 and EN 54-18 requirements, it makes it simpler to watch conditions similar to open circuits and quick circuits which will occur in the system. Many tasks may be performed in the hearth extinguishing installation, such as the management and monitoring of all valves that can interrupt the move of water, water circulate alarm switches, pressure switch, and electric or diesel fire pumps.
By adding two contact monitoring modules to 2 separate relay outputs located above the Maxlogic Conventional Fire Extinguishing Control Panel, one of many modules can be utilized to control errors and the opposite to regulate the fireplace state of affairs, monitoring and management of the extinguishing system via an clever addressable fire detection and alarm system could be carried out successfully.
For more information, go to www.mavili.com.tr/en

Share